Part Number: S9633-B3-MMA-010-ITEM-7-4-7 | Alternate P/N: S9633B3MMA010ITEM747 | Manufacturer: Aish Technologies Ltd | NSN: 5925-01-511-5852 (5925015115852) | NIIN: 015115852 | Item Name : Circuit Breaker | CAGE Code: K0735 | FSC: 5925 Circuit Breakers |
Part number S9633-B3-MMA-010-ITEM-7-4-7 under NSN 5925015115852 and FSC 5925 Circuit Breakers is now available in our ready-to-ship-inventory. This part is a Circuit Breaker manufactured by Aish Technologies Ltd under CAGE Code K0735. To receive a quick quote for this part number, fill out the form
All the fields on this form are mandatory and the value of your quote will be determined primarily by your responses to the Need Parts By and Quantity (ea) fields. So make sure that everything is filled out correctly. A sales representative will contact you within 15 minutes of receiving your request.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
CHARACTERISTICS DATA of NSN 5925-01-511-5852, 5925015115852
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.281 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | VIRGINIA CLASS SUBMARINE |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.950 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED BUSHING |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 26.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | UNDERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3.000 NOMINAL AT 135 PCT ALL LOCATIONS AND 60.000 MAXIMUM AT 135 PCT ALL LOCATIONS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MAGNETIC CIRCUIT BREAKER |
FEAT | SPECIAL FEATURES | USED ON THE UNIT DATA ACQ; BASED ON MIL-PRF-39019/3 |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SCREW |