Buy MHYX4061 Allied Controls Inc Part with NSN 5945-00-834-9097
Part Number: MHYX4061 | Manufacturer: Allied Controls Inc | NSN: 5945-00-834-9097 (5945008349097) | NIIN: 008349097 | Item Name : Relay Electromagnet | CAGE Code: 02288 | FSC: 5945 Relays And Solenoids |
Part number MHYX4061 under NSN 5945008349097 and FSC 5945 Relays And Solenoids is now available in our ready-to-ship-inventory. This part is a Relay Electromagnet manufactured by Allied Controls Inc under CAGE Code 02288. To receive a quick quote for this part number, fill out the form
All the fields on this form are mandatory and the value of your quote will be determined primarily by your responses to the Need Parts By and Quantity (ea) fields. So make sure that everything is filled out correctly. A sales representative will contact you within 15 minutes of receiving your request.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number MHYX4061 with NSN 5945-00-834-9097, 5945008349097
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-834-9097 Item Description: Relay Electromagnet | 5945 | 008349097 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mhyx4061 | 2 | 2 | 5 |
CHARACTERISTICS DATA of NSN 5945-00-834-9097, 5945008349097
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.870 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.060 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.310 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.145 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 3.5 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 26.5 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 30.0 MILLIAMPERES DC SINGLE WINDING |