NSN - 5925-01-295-0434, 5925012950434 of Circuit Breaker
Aviation Axis stocks 203-1-1-61-102-1-1 - Circuit Breaker made by Sensata Technologies Inc with 5925-01-295-0434. Owned and operated by ASAP Semiconductor, we have access to over 2 billion new and after-market parts applicable within the aerospace and defense industries. All our parts are shipped using our premier shipping and supply chain. We offer short lead-times and some of the fastest shipping times in the industry. We are well-equipped to handle any customer situation - including AOG. Submit an RFQ today and expect a response within 15 minutes or less. ASAP - the evolution of purchasing.
Alternative NSN: 5925-01-295-0434 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 012950434 |
NCB Code: USA (01) |
Manufacturers: Sensata Technologies Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
203-1-1-61-102-1-1 | sensata technologies inc | circuit breaker | Avl | RFQ |
Technical Characteristics of NSN 5925012950434
MRC | Criteria | Characteristic |
---|---|---|
AAQL | ||
ABHP | OVERALL LENGTH | 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.150 INCHES MINIMUM AND 0.210 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.770 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.050 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCKPROOF AND VIBRATIONPROOF |
FREQ | FREQUENCY IN HERTZ | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 1.300 OUNCES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |