Buy JL1-A2-A-5-3 Eaton Corporation Part with NSN 5925-00-622-0342
Part Number: JL1-A2-A-5-3 | Alternate P/N: JL1A2A53 | Manufacturer: Eaton Corporation | NSN: 5925-00-622-0342 (5925006220342) | NIIN: 006220342 | Item Name : Circuit Breaker | CAGE Code: 74193 | FSC: 5925 Circuit Breakers |
Part number JL1-A2-A-5-3 under NSN 5925006220342 and FSC 5925 Circuit Breakers is now available in our ready-to-ship-inventory. This part is a Circuit Breaker manufactured by Eaton Corporation under CAGE Code 74193. To receive a quick quote for this part number, fill out the form
All the fields on this form are mandatory and the value of your quote will be determined primarily by your responses to the Need Parts By and Quantity (ea) fields. So make sure that everything is filled out correctly. A sales representative will contact you within 15 minutes of receiving your request.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number JL1-A2-A-5-3 with NSN 5925-00-622-0342, 5925006220342
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-622-0342 Item Description: Circuit Breaker | 5925 | 006220342 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Jl1-A2-A-5-3 | 2 | 9 | 3 |
CHARACTERISTICS DATA of NSN 5925-00-622-0342, 5925006220342
MRC | Criteria | Characteristic |
---|---|---|
AAQL | ||
ABHP | OVERALL LENGTH | 4.636 INCHES MINIMUM AND 4.700 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.168 INCHES MINIMUM AND 1.232 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 2.500 OUNCES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |