Buy SM3-1.5-28-VDC-2 Eaton Corporation Part with NSN 5925-00-845-6612
Part Number: SM3-1.5-28-VDC-2 | Alternate P/N: SM31528VDC2 | Manufacturer: Eaton Corporation | NSN: 5925-00-845-6612 (5925008456612) | NIIN: 008456612 | Item Name : Circuit Breaker | CAGE Code: 74193 | FSC: 5925 Circuit Breakers |
Part number SM3-1.5-28-VDC-2 under NSN 5925008456612 and FSC 5925 Circuit Breakers is now available in our ready-to-ship-inventory. This part is a Circuit Breaker manufactured by Eaton Corporation under CAGE Code 74193. To receive a quick quote for this part number, fill out the form
All the fields on this form are mandatory and the value of your quote will be determined primarily by your responses to the Need Parts By and Quantity (ea) fields. So make sure that everything is filled out correctly. A sales representative will contact you within 15 minutes of receiving your request.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
CHARACTERISTICS DATA of NSN 5925-00-845-6612, 5925008456612
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | KEY INTERLOCK |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.5 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 28.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 750.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNEF |
ADAT | BODY WIDTH | 0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.600 MINIMUM AT 125 PCT SINGLE LOCATION AND 4.000 MAXIMUM AT 125 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS RESISTANT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |