Buy AP44-8443-2 Sensata Technologies Inc Part with NSN 5925-01-387-2095
Part Number: AP44-8443-2 | Alternate P/N: AP4484432 | Manufacturer: Sensata Technologies Inc | NSN: 5925-01-387-2095 (5925013872095) | NIIN: 013872095 | Item Name : Circuit Breaker | CAGE Code: 81541 | FSC: 5925 Circuit Breakers |
Part number AP44-8443-2 under NSN 5925013872095 and FSC 5925 Circuit Breakers is now available in our ready-to-ship-inventory. This part is a Circuit Breaker manufactured by Sensata Technologies Inc under CAGE Code 81541. To receive a quick quote for this part number, fill out the form
All the fields on this form are mandatory and the value of your quote will be determined primarily by your responses to the Need Parts By and Quantity (ea) fields. So make sure that everything is filled out correctly. A sales representative will contact you within 15 minutes of receiving your request.
Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number AP44-8443-2 with NSN 5925-01-387-2095, 5925013872095
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-387-2095 Item Description: Circuit Breaker | 5925 | 013872095 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ap44-8443-2 | 5 | 2 | 5 |
CHARACTERISTICS DATA of NSN 5925-01-387-2095, 5925013872095
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.750 AMPERES AC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
AJWX | Mounting Surface To Terminal End Distance | 1.605 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.250 INCHES MAXIMUM |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
CPRW | Actuator Function | TRIP-RESET |
THSD | Thread Series Designator | UNEF |
ADAQ | Body Length | 1.500 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.375 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 4 WIRE HOOK |
MRC | Decoded Requirement | Clear Text Reply |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.015 MINIMUM AT 200 PCT ALL LOCATIONS AND 5.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.000 INCHES NOMINAL |
Top Part Types
Recently Viewed Parts